Benchtop centrifuges

Specialists in diversity

Hettich manufactures a complete range of benchtop centrifuges for nearly every standard laboratory application. Multiple units, rotors and accessories ensure throughput demands are met, no matter what the volume. Robust and steady temperature control systems ensure your samples are kept at the optimal sample temperature, with both cooled and heated models available. In addition to standard laboratory applications, many specialty applications can be accommodated via our vast library of accessories and our custom built options for those have unique challenges.

ROTOFIX 46

ROTOFIX 46 | 46 H

Robust industrial unit

ROTANTA 460

ROTANTA 460 | 460 R

Superior benchtop for multi-purpose use

ROTINA 420

ROTINA 420 | 420 R

Well equipped for all lab applications

ROTINA 380

ROTINA 380 | 380 R

High speed with space saving design

Hettich UNIVERSAL 320

UNIVERSAL 320 | 320 R

Your universal choice

ROTOFIX 32 A

ROTOFIX 32 A

Rugged and indispensable

Long-term solutions for your evolving laboratory

Hettich offers a wide range of general-purpose benchtop centrifuges suitable for nearly any standard laboratory application. Our products provide reliable, long-term solutions to support your laboratory as it grows and evolves.

   

Speciality applications - capability beyond the bench

Specialty accessories extend our centrifuge capabilities beyond standard clinical labs into agriculture, food and beverage, petrochemical industries, and more. Various temperature control options are also available for precise and reliable results.

Diverse range of accessories for multiple applications
  • Versatile rotors for multiple applications, reducing the need for extra hardware
  • Accessories to meet all capacity and specification requirements
  • Optional bio-containment and phenol-resistant lids for safe handling of hazardous samples
  • Moveable cabinets for extra storage and easy portability
Packages
ROTOFIX 32 A Blood Tube Package 1
  • 1x | 1206 | ROTOFIX 32 A Centrifuge
  • 1x | 1624 | Swing-out rotor, 4-place
  • 4x | 1481 | Buckets 
  • 4x | 1492 | Lids (bioseal)
  • 4x | 1383 | Adapters 5-place 
  • 4x | 1348 | Adapters 4-place
ROTANTA 460 Conical Package 1
  • 1x | 5650 | ROTANTA 460 Centrifuge
  • 1x | 5654 | Swing-out rotor, 4-place
  • 4x | 5651-A | Buckets
  • 4x | 5683 | Adapters 24-place
  • 4x | 5686 | Adapters 10-place
ROTANTA 460 Conical Package 2
  • 1x | 5650 | ROTANTA 460 Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4885 | Buckets
  • 4x | 4839 | Adapters 14-place
  • 4x | 5647 | Adapters 7-place
ROTANTA 460 R Conical Package 1
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4890 | Buckets
  • 4x | 4883 | Lids (bioseal)
  • 4x | 4469 | Adapters 14-place
  • 4x | 4468 | Adapters 7-place
ROTANTA 460 R Conical Package 2
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5654 | Swing-out rotor, 4-place
  • 4x | 5651-A | Buckets
  • 4x | 5683 | Adapters 24-place
  • 4x | 5686 | Adapters 10-place
ROTANTA 460 R Conical Package 3
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4885 | Buckets
  • 4x | 4839 | Adapters 14-place
  • 4x | 5647 | Adapters 7-place
ROTANTA 460 R Blood Tube Package 4
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5654 | Swing-out rotor, 4-place
  • 4x | 5651-A | Buckets
  • 4x | 5652 | Lid (bioseal)
  • 4x | 5685 | Adapters 47-place
  • 4x | 5682 | Adapters 37-place
ROTANTA 460 R Blood Tube Package 5
  • 1x | 5660 | ROTANTA 460 R Centrifuge
  • 1x | 5699-R | Swing-out rotor, 4-place
  • 4x | 4880 | Buckets
  • 4x | 4883 | Lid (bioseal)
  • 4x | 4847 | Adapters 27-place
  • 4x | 4848 | Adapters 22-place
ROTINA 380 Blood Tube Package 1
  • 1x | 1701 | ROTINA 380 Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1751 | Lids (bioseal)
  • 4x | 1783-A | Adapters 16-place
  • 4x | 1763-A | Adapters 13-place
ROTINA 380 Conical Package 2
  • 1x | 1701 | ROTINA 380 Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1771-A | Adapters 9-place
  • 4x | 1772-A | Adapters 4-place
ROTINA 380 R Conical Package 1
  • 1x | 1706 | ROTINA 380 R Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1771-A | Adapters 9-place
  • 4x | 1772-A | Adapters 4-place
ROTINA 380 R Blood Tube Package 2
  • 1x | 1706 | ROTINA 380 R Centrifuge
  • 1x | 1754 | Swing-out rotor, 4-place
  • 4x | 1752 | Buckets
  • 4x | 1751 | Lids (bioseal)
  • 4x | 1783-A | Adapters 16-place
  • 4x | 1763-A | Adapters 13-place
ROTINA 420 Blood Tube Package 1
  • 1x | 4701 | ROTINA 420 Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4780 | Buckets
  • 4x | 4783 | Lids (bioseal)
  • 4x | 4762A | Adapters 26-place
  • 4x | 4763 | Adapters 18-place
ROTINA 420 Conical Package 2
  • 1x | 4701 | ROTINA 420 Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4785 | Buckets
  • 4x | 4769 | Adapters 13-place
  • 4x | 4770 | Adapters 5-place
ROTINA 420 R Blood Tube Package 1
  • 1x | 4706 | ROTINA 420 R Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4780 | Buckets
  • 4x | 4783 | Lids (bioseal)
  • 4x | 4762 | Adapters 26-place
  • 4x | 4763 | Adapters 18-place

 

ROTINA 420 R Conical Package 2
  • 1x | 4706 | ROTINA 420 R Centrifuge
  • 1x | 4784-A | Swing-out rotor, 4-place
  • 4x | 4785 | Buckets
  • 4x | 4769 | Adapters 13-place
  • 4x | 4770 | Adapters 5-place
UNIVERSAL 320 Blood Tube Package 1
  • 1x | 1401 | UNIVERSAL 320 Centrifuge
  • 1x | 1494 | Swing-out rotor, 4-place
  • 4x | 1425 | Buckets
  • 4x | 1438 | Adapters 7-place
  • 4x | 1441 | Adapters 7-place
UNIVERSAL 320 Blood Tube Package 2
  • 1x | 1401 | UNIVERSAL 320 Centrifuge
  • 1x | 1554 | Swing-out rotor, 4-place
  • 4x | 1560 | Buckets
  • 4x | 1561 | Lids (bioseal)
  • 4x | 1589 | Adapters 7-place
  • 4x | 1588 | Adapters 5-place
UNIVERSAL 320 Conical Package 3
  • 1x | 1401 | UNIVERSAL 320 Centrifuge
  • 1x | 1324 | Swing-out rotor, 4-place
  • 4x | 1398 | Buckets
  • 4x | 1483A | Adapters 4-place
  • 4x | 1484 | Adapters 1-place
UNIVERSAL 320 R Conical Package 1
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1554 | Swing-out rotor, 4-place
  • 4x | 1560 | Buckets
  • 4x | 1561 | Lids (bioseal)
  • 4x | 1577 | Adapters 2-place
  • 4x | 1579 | Adapters 1-place
UNIVERSAL 320 R Blood Tube Package 2
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1494 | Swing-out rotor, 4-place
  • 4x | 1425 | Buckets
  • 4x | 1438 | Adapters 7-place
  • 4x | 1441 | Adapters 7-place
UNIVERSAL 320 R Conical Package 3
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1324 | Swing-out rotor, 4-place
  • 4x | 1398 | Buckets
  • 4x | 1483A | Adapters 4-place
  • 4x | 1484 | Adapters 1-place
UNIVERSAL 320 R Blood Tube Package 4
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1624 | Swing-out rotor, 4-place
  • 4x | 1481 | Buckets
  • 4x | 1492 | Lids (bioseal)
  • 4x | 1383 | Adapters 5-place
  • 4x | 1348 | Adapters 4-place
UNIVERSAL 320 R Blood Tube Package 5
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1554 | Swing-out rotor, 4-place
  • 4x | 1560 | Buckets
  • 4x | 1561 | Lids (bioseal)
  • 4x | 1589 | Adapters 7-place
  • 4x | 1588 | Adapters 5-place
UNIVERSAL 320 R Blood tube package 6
  • 1x | 1406 | UNIVERSAL 320 R Centrifuge
  • 1x | 1494 | Swing-out rotor, 4-place
  • 4x | 1427 | buckets
  • 4x | 1421 | Lids (bioseal)
  • 4x | 1732 | Adapters 8-place
  • 4x | 5231 | Adapters 6-place
FAQ
How do benchtop centrifuges differ from small centrifuges?

Hettich benchtop centrifuges stand out for their versatility. Equipped with a wide range of accessories, they can handle nearly all standard applications. They are commonly used in clinical laboratories, food labs, and agricultural settings.

What sets them apart from small centrifuges are their larger capacity, the option to cool or heat samples, and their higher speeds, making them suitable for more demanding laboratory tasks.

During centrifugation, the rotor chamber heats up due to air friction and motor-generated heat. The longer or faster the run, the higher the temperature. Standard laboratory centrifuges have an air cooling system to remove some of this heat.

However, many samples are thermally sensitive and must be processed within a specific temperature range. Refrigerated centrifuges with a coolant circuit and controlled cooling unit maintain these temperatures. Depending on the device, the preferred centrifugation temperature can be set anywhere between -20°C and +40°C, ensuring sample integrity.

The actively heated centrifuge heats up quickly from room temperature to 90°C.

     

Hettich offers three different cytodiagnostic systems. 

They can be used in the following centrifuges, depending on the system: 

  • ROTOFIX 32 A
  • UNIVERSAL 320 | 320 R
  • ROTINA 380 | 380 R
  • ROTINA 420 | 420 R
  • ROTANTA 460 | 460 R
  • ROTIXA 500 RS


Our cytology brochure provides a summary of these options.

Product Support

Do you want to know more? Then reach out to us! Whether you prefer to send us a message, give us a call, or dive right into configuring your Centrifuge combination using our intuitive Configurator, we're here to ensure your experience is seamless and successful.

Centrifuge Configurator

RCF / RPM Calculator

Product catalog

Cleaning and care of centrifuges